SlimFit Commercial Condensing Gas Boiler

  • Default

    671x386_WM_slimfit_mainimage

  • Default

    671x386_WM_SlimFit_1A

  • Default

    671x386_WM_SlimFit_1B

  • Default

    671x386_WM_SlimFit_2

  • Default

    671x386_WM_SlimFit_3

  • Default

    671x386_WM_SlimFit_4

  • Default

    671x386_WM_SlimFit_5

  • Default

    671x386_WM_SlimFit_6

  • Default

    671x386_WM_SlimFit_8

  • Default

    671x386_WM_SlimFit_9

  • Default

    671x386_WM_SlimFit_Closeup

  • Default

    671x386_WM_SlimFit_Closeup_Controls

  • Default

    671x386_WM_SlimFit_Inside

  • Default

    671x386_WM_SlimFit_inside_closeup

  • Default

    671x386_Revit_Downloads

Image 1of 15
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
Product Type:

commercial

SlimFit Commercial Condensing Gas Boiler
 
Where to Buy
Contact us today to obtain a contractor or distributor in your area.
LEARN MORE

Installs FAST, Built to LAST

  • Easy to Install - Designed for fast, easy installation in commercial and institutional settings
  • Easy to Own - Durable and reliable, ready for a lifetime of smooth operation
  • Right Fit for Retrofits - Fastest, easiest solution for limited-space retrofits
  • Up to 96.1% Combustion Efficiency
  • Up to 95.8% Thermal Efficiency
  • 1,000,000 TO 2,000,000 BTU/HR
  • Low NOx ‹ 20 PPM
  • Modulating Burner with 6:1 Turndown Ratio
  • CSD-1 Compliant is Standard
  • SOLA-Control Flexibility with 7” LCD Touch Screen
  • Fully Customizable Outdoor Reset Curve
  • Lead/Lag Capability up to 8 Boilers with lead boiler rotation
  • Remote modulation through BAS using Modbus or BACnet
  • High limit temperature control with manual reset, fixed 200 degree F
  • PVC, CPVC, PP or SS (AL29-4C) materials approved for Direct Vent and Direct Exhaust
  • Approved for Common Venting 
  • Fast & Easy Out of the Box Installation
  • Lightweight, Compact Design Packaged Boiler Requiring Minimal Clearance
ModelAHRI Input Max (MBH)AHRI Input Min (MBH)AHRI Gross Output (MBH)Net AHRI (MBH)Combustion EfficiencyThermal EfficiencyVent MaterialVent Air SizeVent Air LengthMin Gas Pressure (w.c.)Max Gas Pressure (w.c.)Shipping Weight (lbs.)Length (in.)Width (in.)Height (in.)
SF10001,00016795883396.1%95.8%PVC, CPVC, PP or SS (AL29-4C)6" or 8"100' or 150'3"14"1,13077.9332.5651.87
SF15001,5002501,4371,25095.9%95.8%PVC, CPVC, PP or SS (AL29-4C)8"100'3"14"1,31077.9332.5651.87
SF20002,0003331,9061,65795.8%95.3%PVC, CPVC, PP or SS (AL29-4C)8"100'3"14"1,51090.1032.5651.87

Click here for information on Sentinel products

Introduction

Unloading and Unpacking Boiler

Boiler Components Overview

Preparing Boiler Location

Water Piping

Venting and Air Intake

Gas Piping

Field Wiring

SOLA Overview

SOLA Controls Interface and Menus

SOLA Controls Express Setup

Start Up Procedures and Final Checks

Maintenance

Troubleshooting